Ambulance emergency patient monitor

Sale!

$1,800.00 $1,600.00

ECG


Lead mode
3-Lead :I,II,III
5-Lead:I,II,III,AVR,AVF,AVL,V
12-Lead:I,II,III,AVR,AVF,AVL,V1~V6
ECG waveform 
2 channals(normal),7 channals,12 channals  

 

Filter mode

Diagnosis: 0.05 ~ 100HZ
Guardianship: 0.5 ~ 40HZ
Surgery: 1 ~ 20HZ
Strong filter: 5 ~ 20HZ
Trap wave
50HZ, 60HZ
Support
Pacing patient ,ST analysis
Waveform speed
6.25mm / s, 12.5mm / s, 25.0mm / s, 50mm / s
Waveform Gain
Auto, x0.125, x0.25, x0.5, x1, x2, x4

Arrhythmia Analysis

Non-pacing patients (total 11kinds) Park, ventricular fibrillation / ventricular tachycardia, ventricular rhythm, two room early, multiple room early, early morning two law, room early triple law, R ON T, multiple PVCs , Tachycardia, bradycardia, loss of pacing, pacing patients (a total of 5 species) Park, ventricular tachycardia, bradycardia, pacemaker without pacing, pacemaker without capture
HR measurement range of adults:
15 ~ 300bpm children / newborns: 15 ~ 350bpm
HR measurement accuracy
± 1bpm or ± 1%, take the big
ST measurement range
-2.0 ~ 2.0mv
ST measurement accuracy
-0.8 ~ 0.8mv: ± 0.02mv or ± 10%, take the big

 

RESP

measurement method
Chest impedance method
Measuring lead
Lead II guide
Waveform speed
6.25 mm / s, 12.5 mm / s, 25.0 mm / s
Choking alarm
15 seconds, 20 seconds, 25 seconds, 30 seconds, 35 seconds, 40 seconds, off
RR measurement range
Adults: 0 ~ 120rpm pediatric / neonatal: 0 ~ 150rpm
RR measurement accuracy
7 ~ 150rpm: ± 2rpm or ± 2% to take the big 0 ~ 6rpm: not defined
TEMP
channel number
1 channel
measurement range
0 ~ 50 ℃
measurement accuracy
± 0.1 ℃ (without sensor)

 

SPO2

measurement range
0 ~ 100%
measurement accuracy
70 ~ 100%: ± 2% (adult / pediatric)
PR measurement range
70% ~ 100%: ± 3% (neonatal) Less than 70%: Not defined
PR measurement accuracy
20 to 255 bpm
Weak perfusion
± 1bpm or ± 1%, whichever is greater
Pulse tone pitch tone
0.02 to 20%
Pulse tone
0~9
optional module
support Nellcor and Masimo

 


NIBP

Measurement methods
Oscillation method
Pressure unit
MmHg, Kpa
Measurements
Systolic blood pressure (SYS), diastolic blood pressure (Dia), mean pressure (Mean)
Operating mode
Manual mode, automatic mode, continuous mode
Automatic mode measurement interval
1/2/3/4/5/10/15/30/60/90/120/180/240/280 minutes

Measuring range (mmHg)

 
Systolic blood pressure
diastolic blood pressure
mean pressure
adult
40~270
10~210
20~230
Children
40~200
10~150
20~165
Newborns
40~135
10~95
20~105
measurement accuracy
Maximum average error: ± 5mmHg, Maximum standard deviation: ± 8mmHg
Double overvoltage protection
support
Software overvoltage protection
Adults: 297 ± 3mmHg, Pediatric: 240 ± 3mmHg ,Newborns: 147 ± 3mmHg

 

Standard Packing

5 lead American standard ECG lead wire X1
Adult finger clip type oxygen probeX1
10K body surface temperature probe X1
Adult disposable electrocardiographic electrode X1
Adult blood pressure cuff X1
3M gray blood pressure extension tube X1
Ground wire X1
Lithium battery / 2600MAH 11.1V X1
2M American standard power cord X1
 

Description

Quick Details
Type:
Examination Therapy Equipments
Brand Name:
JQ
Model Number:
JQ-6213
Place of Origin:
Shanghai, China (Mainland)
Instrument classification:
Class II
Product name:
Ambulance patient monitor
ECG:
3-Lead,5-Lead,12-Lead
Resp:
yes
SpO2:
yes
LCD:
8.4inch TFT
size:
173x274x152mm
Alarm system:
audible and visual alarm
With Lithium battery:
2600MAH 11.1V X1
Warranty:
2 Years

Additional information

Description

JQ-6213 Plus Examination Therapy Equipments Ambulance emergency patient monitor
1. 8.4'' Color TFT Display
2.Apply for Patient Emergency Transport Theatre (Portable)
3.Configuring a continuous bedside monitoring with ECG
4.Could add ETCO2,NELLCOR/MASIMO Spo2,CMS,printer modules
5.wifi connection to centrol monitor system is optional
6.Switching power supply